The details of the DOT 406 specification can be found in 49 CFR 178 sub-parts 345 and 346. Transfer Flow refueling tanks meet or exceed the testing and certification requirements specified in 49 CFR 178.803. Defective containers shall be removed from service. If you have comments or suggestions on how to improve the www.ecfr.gov website or have questions about using www.ecfr.gov, please choose the 'Website Feedback' button below. ATTA, Inc. Special Permit #20416 is valid for use with Diesel, Ethanol, Gasoline, Kerosene, Methanol and Aviation Fuel. The cabinet should also be covered with a fire resistant paint and it should be discarded if the surface is chipped. The Two- 2 bungs allow for reversing the fuel fill cap and fuel transfer pump to the side you prefer best. The can must have a flash-arresting screen and a spring-closing lid, and be able to safely relieve internal pressure. Ohio Admin. These guidelines must be followed by all employees on the site. These general requirements mandate that the fuel tank be mounted in a safe location behind the front axle without extending out from the vehicle, where spilled fuel will be kept away from the exhaust, and with fill pipes on the outside of the vehicle. AT80RTF - DOT Legal Transfer Tank . First, its important to understand the differences between bulk and non-bulk packaging. We believe in the value of NHTSAs Fuel System Integrity testing utilizing the FMVSS 301 standards. (b) Test and inspections for metal, rigid plastic, and composite IBCs. [Amdt. Section 393.67: Liquid fuel tanks. If you require an alternative version of files provided on this page, please contact. The threads of all fittings must be Dryseal American Standard Taper Pipe Thread or Dryseal SAE Short Taper Pipe Thread, specified in Society of Automotive Engineers Standard J476, as contained in the 1971 edition of the SAE Handbook, except that straight (nontapered) threads may be used on fittings having integral flanges and using gaskets for sealing. The flash-point, temperature at which fuel can vaporize and form an ignitable mixture, for gas is less than -40C (-40F). The DOT has issued Transfer Flow DOT Special Permit SP-11911 to manufacture and sell refueling tanks that can store gas, diesel, ethanol, methanol, kerosene and aviation fuel. Product development confirmed by FMVSS 301 has been instrumental in Transfer Flow designing the safest aftermarket fuel tanks and fuel systems available. If you want to keep most of your bed space check out our more slender aluminum fuel tank designs, some only require 9. Commercial VehiclesPart 393.67 of the FMCSA regulations cover the standards for all fuel tanks, including diesel and auxiliary tanks, on commercial vehicles. Group Y: Meets tests for Packing Groups (PG) II and III. 1 CFR 1.1 PDF Federal Highway Administration, DOT 393 - govinfo.gov This part also requires that the fuel lines be installed where they will not interfere with towing, away from the passenger compartment on buses, and in a protected and secured area. (8) Safety venting system. Engines shall be stopped and operators shall not be on the equipment during refueling operations. Each liquid fuel tank shall be legibly and permanently marked by the manufacturer with the following minimum information: (2) The manufacturer's name on tanks manufactured on and after July 1, 1989, and means of identifying the facility at which the tank was manufactured, and. Defective inner receptacles must be replaced in accordance with paragraph (d) of this section or the entire IBC must be removed from service. UN 31A GROUP Y INTERMEDIATE BULK CONTAINER (IBC). There is something else you should ensure your fuel transfer tank has, -baffles. Organization and Purpose Leaking containers shall not be used. (B) IBC walls are free from defects in wood. 6. Permanent protection shall be provided for fittings on removable containers. Additionally, all commercial vehicle diesel tanks must be properly marked with the manufacturers name and location the date of manufacture and a certificate stating that the tank conforms to the FMCSA standards. Our standard fuel tanks range from 38 to 110 gallons. (iv) Drains or other bottom fittings must be installed in a flange or spud designed to accommodate it. The rectangle Refueling Transfer Tank is the most popular in the lineup. Failure to have refueling tank retested every 2.5 years will void warranty. (2) An external visual inspection must be conducted initially after production and every 2.5 years starting from the date of manufacture or the date of a repair conforming to paragraph (d)(1) of this section to ensure that: (i) The IBC is marked in accordance with requirements in 178.703 of this subchapter. The equipment can only be approved by certain bodies, such as a nationally recognized testing laboratory, for example, Factory Mutual Engineering Corp, or Underwriters Laboratory Inc., or Federal agencies such as Bureau of Mines or U.S. Coast Guard. Warranty card must be returned to ATTA, Inc. within 30 Days of purchase. (C) Fabric used to construct the IBC is free from cuts, tears and punctures. The official, published CFR, is updated annually and available below under A legal fuel can must be approved by a nationally recognized testing laboratory, such as United Laboratory , to satisfy OSHA requirements. Except for a DOT Specification 56 or 57 portable tank, a DOT Specification portable tank manufactured after January 1, 1992, used for materials meeting the definition for Division 6.1 liquids, Packing Group I or II, Class 2 gases, or Class 3 or 4 liquids, must be equipped with a reclosing pressure relief valve having adequately sized venting . Web Design & Development by Americaneagle.com. Alternative procedures which assure that equipment meets the required performance standards may be used. Wheels: Polished aluminum wheels are installed for a beautiful shine and rust prevention. This includes areas where fuel is received or dispensed. Diesel fuel has an autoignition temperature of approximately 260C. Heres what we figured out that will hopefully give you some insight into staying safe and legal, or should we say, citation free. From a vehicle performance standpoint, gravity feed fuel systems can adversely affect federally mandated, manufacturer implemented, on-board vehicle diagnostic systems. the hierarchy of the document. (5) A gasoline tank, other than a side-mounted gasoline tank, manufactured before January 1, 1973, and mounted on a vehicle other than a bus must conform to the rules in paragraphs (c) (1) through (10), inclusive, of this section. V25 This 12VDC fuel transfer pump cranks out 25 GPM withstand extreme temperatures from -40F to 125F (see XTS model). Gas Transfer Tank | DOT Certified | JME Ellsworth will bring you to those results. Each fuel tank must be equipped with a nonspill air vent (such as a ball check). Hydrogen Specifically Listed as a hazardous material in HMR (DOT PHMSA) Certification and Posting of Fuel Ratings Federal Trade Commission (FTC), 16 CFR Part 306 Related to hydrogen as a fuel, but also transfer of fuel between entities Hydrogen Not Included; even for alternative automotive fuel 13 Each IBC constructed in accordance with a UN standard for which a test or inspection specified in paragraphs (b)(1), (b)(2) and (b)(3) of this section is required may not be filled and offered for transportation or transported until the test or inspection has been successfully completed. dot-cargo-tank-test-and-inspection-brochure.pdf, Soleus Air 8000 Btu Portable Air Conditioner, Portable Oxygen Concentrator For Sale Used. Our split tanks are designed for transporting and refueling two separated liquids legally on your flat bed or in the bed of your pickup truck. Use the form below to enter your vehicle details. Quick view Compare Choose Options. UL 142 AND 2085: Underwriters Laboratories (UL) standards 142 and 2085 DO NOT APPLY to mobile fuel storage containers, only to stationary above-ground storage tanks as specified in the scope of the UL 142 standard, part 1.7. If you have questions or comments regarding a published document please PDF Federal Motor Carrier Safety Administration, DOT 393 - GovInfo You can employ the use of a bungee cord, if necessary, to anchor the fuel tank and ensure safety when deployed on a vehicle in motion. Only approved containers and portable tanks can be used to store flammable liquids. (a) Application of the rules in this section. DOT Cargo Tank Test and Inspection Brochure | FMCSA Other Regulations Relating to Transportation, Pipeline and Hazardous Materials Safety Administration, Department of Transportation, Continuing Qualification and Maintenance of Packagings, https://www.ecfr.gov/current/title-49/subtitle-B/chapter-I/subchapter-C/part-180/subpart-D/section-180.352. Electronic Code of Federal Regulations (e-CFR), Subtitle B - Other Regulations Relating to Transportation, CHAPTER III - FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION, SUBCHAPTER B - FEDERAL MOTOR CARRIER SAFETY REGULATIONS, PART 393 - PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION, Kan. Admin. Containers near the engine or exhaust system shall be shielded against direct heat radiation. (eg: The IBC must be externally inspected for cracks, warpage, corrosion or any other damage which might render the IBC unsafe for transportation. (e) Requirements applicable to routine maintenance of IBCs. When removable fuel containers are used, the escape of fuel when containers are exchanged shall be minimized by: Automatic quick-closing couplings (closing in both directions when uncoupled) in fuel lines; or. (a) Application of the rules in this sec-tion. L-shape and Rectangle split fuel tanks are available. 2 Diesel Fuel . So how do you make sure that youre preventing any potential hazards that could arise during this process? Alternative procedures which assure that equipment meets the required performance criteria may be used. 110 Gallon DOT Aluminum Rectangular Refueling Transfer Tank w/ Optional Pump. Each IBC must be visually inspected prior to first use and permitted reuse, by the person who places hazardous materials in the IBC, to ensure that: (1) The IBC is marked in accordance with requirements in 178.703 of this subchapter. 110 Gallon Fuel Transfer Tank - DOT Certified for Gas or Diesel w/ Fill-Rite FR1210 Pump. All stitched seam-ends must be secure. Get the latest updates on new products and upcoming sales. In case of spillage, filler caps shall be replaced and spillage disposed of before engines are started. Special Permit issued by the US Department of Transportation, All polished aluminum DP body construction, Commercial grade lockable vent/prevent filler cap, Fully baffled to reduce movement of contents, Two-2 npt reinforced bungs for superior strength, Clean and free of debris inside and outside of the tank, Designed for use with transfer pumps up to 30 lbs , Polished industrial stainless locking handles. (f) Retest date. Use the navigation links in the gray bar above to view the table of contents that this content belongs to. Regs. (11) Markings. Such IBCs ARE SUITABLE for the transport of Gasoline and AvGas on public roadways per FEDERAL transportation requirements per 49 CFR 173.242 subpart . site when drafting amendatory language for Federal regulations: Fuel containers shall be secured to prevent their being jarred loose, slipping or rotating. Code Trans Sec. (iv) The person performing the tests and inspections after the repair must durably mark the IBC near the manfacturer's UN design type marking to show the following: (A) The country in which the tests and inspections were performed; (B) The name or authorized symbol of the person performing the tests and inspections; and. The motors of all equipment being fueled must be shut down for the entirety of the process. Smoking and open flames shall be prohibited in areas used for fueling, fuel storage or enclosed storage of equipment containing fuel. If the body of a fuel tank is readily visible when the tank is installed on the vehicle, the tank must be plainly marked with its liquid capacity. . 49 CFR 173.241 specifies that non-DOT specification cargo tank motor vehicles are suitable for the transport of such fuels. Always use proper venting procedures (gas cap and/or rollover emissions valves) to prevent over pressurization of the tank. The rules in this section apply to tanks containing or supplying fuel for the operation of commercial motor vehicles or for the operation of auxiliary equipment installed on, or used in connection with commercial motor vehicles. (d) Requirements applicable to repair of IBCs. Pressing enter in the search box Customer safety and fuel system legality continue to be our priorities after more than 175,000 fuel systems sold and more than 30 years in business. citations and headings If this type of work is expected then its not a safe area to store fuel. DOT Regulations for Mobile Fuel Containers. DOT LEGAL TRANSFER TANKS - attatank.com To find out more about our special permit visit our Special Permit page. It is important to be aware of and have some knowledge of state and federal regulations regarding the transportation of fuel tanks, whether filled or empty, with residual compound. Tank saddlesare also a legal requirement. (1) A liquid fuel tank manufactured on or after January 1, 1973, and a side-mounted gasoline tank must conform to all . 10 Tips To Know When Using Fuel Transfer Tank - Fueloyal 49 CFR 173.242 cites DOT 406 tanks as suitable for the transport of such materials. Transfer Flow refueling tanks meet or exceed the testing and certification requirements specified in 49 CFR 178.803. (ii) Each fiberboard IBC must be inspected to ensure that: (A) Fluting or corrugated fiberboard is firmly glued to facings. Not using the proper gas cans can be a costly mistake both physically and financially. (i) Each flexible IBC must be inspected to ensure that: (A) Lifting straps if used, are securely fastened to the IBC in accordance with the design type. 1917.156 (a) (2) In case of spillage, filler caps shall be replaced and spillage disposed of before engines are started. Choosing an item from 3. A properly functioning rollover valve will close when the fuel level reaches the float of the valve. Tanks of this nature can hold large supplies of fuel, for up to weeks or even months. The E-Cube Mobile is authorized for the transport of PG II and III liquids such as diesel and Jet-A as a UN 31A Group Y IBC. Code 4501-52-01 - 4501-52-01 - Requirements for annual inspection of buses; incorporated materials. Screw threads or a bayonet-type point are methods of conforming to the requirements of paragraph (c) of this section. Heres the short take on the legal aspect. is available with paragraph structure matching the official CFR This letter concerns a 150-gallon diesel fuel tank mounted on a trailer that provides fuel for a diesel engine pump also mounted on a trailer. 1917.156 - Fuel handling and storage. | Occupational Safety and Health The in-page Table of Contents is available only when multiple sections are being viewed. DOT Refueling Tanks - Aluminum Tank Industries The nozzle, in particular, must be an automatic-closing type, without a latch open device. For safety reasons, only approved closed containers of a maximum capacity of five gallons can be used. Liquefied gas powered equipment shall be fueled only at designated locations. Each fuel tank must be equipped with a nonspill air vent (such as a ball check). Here is a summary of the laws in place for storing fuel in containers or a fuel tank on construction sites. These are requirements for thestorage of flammable and combustible liquids such as gasoline or diesel as outlined by OSHA. Fuel storage and transfer on construction sites can be a fire hazard and could cause an explosion if the proper safety guidelines are not complied with. Its important to follow these carefully when dealing with fuel storage on construction sites. (2) A diesel fuel tank manufactured before January 1, 1973, and mounted on a bus must conform to the rules in paragraphs (c)(7)(ii) and (d)(2) of this section. Never apply more than 3 psi to any Transfer Flow tank. of an exhaust system. (1) Except for flexible and fiberboard IBCs and the bodies of rigid plastic and composite IBCs, damaged IBCs may be repaired and the inner receptacles of composite packagings may be replaced and returned to service provided: (i) The repaired IBC conforms to the original design type, is capable of withstanding the applicable design qualification tests, and is retested and inspected in accordance with the applicable requirements of this section; (ii) An IBC intended to contain liquids or solids that are loaded or discharged under pressure is subjected to a leakproofness test as specified in 178.813 of this subchapter and is marked with the date of the test; and. 1805, 59 FR 38079, July 26, 1994, as amended at 64 FR 10782, Mar. (ii) Required performance. A full tank of fuel should not be placed in areas where workers are present or where they pass through. Group Y IBCs are authorized to transport UN Packaging Group II and III materials, which includes Gasoline and No. We Strive to provide you with the peace of mind in knowing anytime/anywhere your truck is inspected, you will have a legal fuel tank and fuel system. Failure to send ATTA, Inc. retesting documentation within the 2.5 year limit will void ATTA, Inc. manufacture warranty. Joints of a fuel tank body must be closed by arc-, gas-, seam-, or spot-welding, by brazing, by silver soldering, or by techniques which provide heat resistance and mechanical securement at least equal to those specifically named.